Unit software
The update file contains the complete software for all Series 5 products. The latest software can be obtained from your country representative (www.hb-therm.com) or you can download it directly from this page. For information on how to update the software, see the instruction manual.
- Download latest version → SW51-2.zip
Software modifications
The individual software versions with their modifications are listed here and sorted according to the date of release (latest version at the top).
release
Remarks
-
New functions
- quality test extended with HB-TP180 for HB-200/230Z2B.
improvements
- various texts adapted in all languages.
- various improvements in final series testing (not relevant for end customers).
Bug fixes
- remote operation active, but cannot be deactivated as the function is not shown in the [Functions] menu (only known for units with additional ZC equipment).
- In directly cooled units (HB-100X) with additional ZG equipment, the compressed air valve is controlled during pressure relief.
release
Remarks
- various improvements in final series testing (not relevant for end customers).
New functions
-
improvements
-
Bug fixes
-
release
Remarks
-
New functions
- special execution 'Safety safety cut-out via external contact':
The unit has an additional relay that enables a safety cut-out. In normal operation, the relay is supplied with an external 24 VDC voltage. If this voltage fails, the relay falls off and switches off the unit via a potential-free contact. - Integration of external Flow meter Flow-5 as “integrated” [DFM Recognition] with the function [Simulate DFM As Device]:
It is adjustable whether the temperature is transferred from the main line or from the return line of the individual measurement circuits to the machine control.
improvements
- Measurement evaluation of flow rate measurement for water units 200/230 °C improved.
- The ST-DOS K-374 water treatment agent was added as a pre-selectable agent.
- The setting range for the [Sensor External Offset] parameter has been extended to -10... +10 K.
Bug fixes
- The temperature setting is not saved if the [Temp. Nom. Value Limitation] parameter is changed.
- Some units in Euromap 82.1 are not completely translated.
- The switching unit Vario-5 outputs the error message “overtemperature electrical part” even though the monitoring is switched off.
- A multiple shutdown command via Euromap 82.1 causes the temperature control unit to be switched on.
- Sporadic edition of maintenance notifications for 200/250 °C oil units.
- The Euromap 82.1 data model has been adapted for units without frequency control so that there are no relevant functions and actual values for frequency converter.
- The integration of external Flow-5 Flow meter Flow-5 with more than 8 measurement circuits via protocol 1 does not work.
The actual value of the external sensor is always transmitted via the PROFIBUS interface, regardless of the sensor type set.
- The measurement variables were not always compared when the measured values obtained from the quality check with the checking facility (HB-TP180/200) were adopted at a later date and not immediately after the quality check was completed.