Basic data

type
flow meter

HB-FM100R61/L61

HB-FM160R61/L61

HB-FM180R61/L61

flow controller

HB-FR100R61/L61

HB-FR160R61/L61

HB-FR180R61/L61

Execution


regional indicator symbol letter l Left
regional indicator symbol letter r Right

Dimensions (height/width/depth)

4 circuits

264 mm / 239 mm / 175 mm

6 circuits

364 mm / 239 mm / 175 mm

8 circuits

464 mm / 239 mm / 175 mm

Weight max.
4 circuits

11 kg / 12 kg

6 circuits

15 kg / 17 kg

8 circuits

18 kg / 20 kg

Environment
Temperature

5–40 °C

Relative humidity

35–85 % RH

(non-condensing)

temperature measurement
resolution

0,1 °C

Tolerance

±0.2 °C (after adjustment with the reference system used by HB-Therm for the final test)

Flow rate measurement
resolution

0,1 L/min

Tolerance± (5% of measured value + 0,1 L/min)
nominal measurement range per circuit

0,4–40 L/min

Hydraulic data
connection main manifold
thread

G1¼

(optional G1)

Resistance

20 bar, 100 °C

(120°C for a short time)

20 bar, 160 °C

(180°C for a short time)

25 bar, 180 °C

(200 °C for a short time)

connection circuits
thread

Resistance (including external heat transfer circuit)

20 bar, 100 °C 

(120°C for a short time)

20 bar, 160 °C

(180°C for a short time)

25 bar, 180 °C 

(200 °C for a short time)


Electrical data

warningConnect only to a power supply in accordance with the specified connection values. The specific connection values are also shown on the nameplate

power supply

24 VDC via power supply or machine control

(info)To power the Flow-6, we recommend either using our T30007 power supply (90 W) or connecting it directly to the machine control (24 VDC).

Electrical power (HB-FM)

4, 6, 8 circuits

7 W / 0,3 A

Electrical output (HB-FR)

4 circuits

45 W / 1,9 A

6 circuits

65 W / 2,7 A

8 circuits

84 W / 3,5 A

Protection class

IP 44

Overvoltage category

I

Degree of contamination

2