ATTENTION!

The hydraulic and electrical requirements must comply with the information in the technical data.

hydraulic

Have hydraulic connections made by Qualified hydraulic personnel under the following conditions:

  • Screw connections and hose lines must comply with the specifications in the technical data (pressure and temperature resistance).
  • Use assembly paste for all screw connections, as they tend to get stuck (especially stainless steel/stainless steel).
  • Secure hose connections sufficiently from direct contact to avoid the danger of scalding.

procedure:

  1. Install the Flow-6 flow meter/controller at the desired installation location.
  2. Connect individual tool circuits from the consumer to circuits 1—n.
  3. Connect the water supply to the IN and OUT main distributors.

Electrical

Have electrical connections made by qualified Qualified electrical personnel under the following conditions:

  • Make the electrical connection only after the hydraulic connections have been made.
  • Power supply must comply with the information on the nameplate and in the technical data

procedure:

  1. Connect control cable
  2. Establish a power supply

main distributor

IN

Water supply inlet

OUT

Water supply output
Individual circuits 1—nINTemperature control channel inlet
OUTTemperature control channel output
Electricity Supply24 VDC

Power supply via power supply unit or machine control

24 VDC (Pin 1 = 0 VDC; Pin 2 = 24 VDC; Pin 4= Earth (PE))