Download PDF
Download page T24226 replacement temperature sensor BT6.
T24226 replacement temperature sensor BT6
qualification
Qualified personnel
Material
Pos | Description | Article | Number |
---|---|---|---|
01 | Pt 1000 temperature sensor, 1.0 m | T24226 | 1 |
Required material
- Torx screwdriver size 20
- Open-end wrench, size 10
procedure
ATTENTION!
Working with the unit requires knowledge of the safety instructions and quick guide. That's why:
Read the safety instructions and quick guide carefully before starting any work. The basic requirement for safe work is compliance with all safety instructions and careful action by qualified qualified personnel to prevent accidents involving personal injury and property damage.
Cool down and empty the unit
- On the basic screen, tap the function button ().
- On the basic screen, tap the function button ().
→ The unit cools down and evacuation the mold before switching it off.
Check pressure and switch off unit
- Select [Display] > [Actual Values] > [System Pressure].
→ The system pressure must display 0.0 (±0.1) bar. - The pressure shown by the pressure gauge must be 0.0 (+0.3) bar.
- Switch off the main switch (QS 1), pull out the mains-connector.
Remove covers and open the front
- Remove covers from the unit (→ Open unit).
- Open the front door and fold the front completely down by loosening the two Torx screws.
Replace temperature sensor (BT 6)
- Remove the temperature sensor cable from the GIF-61 (A 4) unit board and remove the cable tie to completely remove the cable.
- BT 6 temperature sensor → slot X36.1
- Remove and remove the temperature sensor.
ATTENTION!
Screw connections, in particular combinations of stainless steel/stainless steel or steel/stainless steel, tend to get stuck or get stuck when operation for a long time at high temperatures. That's why:
Use appropriate lubricants
- Install a new temperature sensor and tighten
- Transfer cable lettering from the old temperature sensor to the new one.
- Route and connect the cable from the temperature sensor to the GIF-61 (A 4) unit board.
- BT 6 temperature sensor → slot X36.1
- Re-attach removed cable ties or replace them with new ones.
- Fold up the front and secure 2x Torx screws.
Check tightness and function
- Connect the mains-connector and switch on the main switch (QS 1).
- Switch on the unit using the I/O button (), check the tightness and function of the unit.
Calibrate temperature measurement
- Calibrate the temperature sensor if necessary (→ Temperature measurement).
ATTENTION!
Danger incorrect calibrating
An incorrect calibrating may cause the unit to malfunction. That's why:
- Verify calibrating
switch off unit and install covers
-
Switch off the unit using the I/O button ().
→ The unit switches off and, if necessary, is cooled and depressurised. - Switch off the main switch (QS 1).
- Re-attach covers from the unit (→ Open unit).