Faults are displayed on the basic screen in the status field and through the floor (Spotlight) lighting. In addition, an acoustic alarm (horn) informs the operator in the event of a fault. Tapping on the status field (symbol ) opens the info system. The information system displays general device information as well as information about faults and warnings that occur.
A distinction is made between the following warning levels, which trigger appropriate reactions (→ fault table)
Alert level
5
10
13
20
30
33
35
status field (Spotlight)
Yellow
Yellow
Yellow
Red
Red
Red
Red
heating
Off
-
-
Off
Off
Off
Off
pump
-
-
-
-
Off
Off
Off
cooling
-
-
-
-
Off
Off
Off
horn
-
Active
Active
Active
Active
Active
Active
alarm contact
-
Active
Active
Active
Active
Active
Active
Alarm on interface
-
Active
Active
Active
Active
Active
Active
Alarm acknowledgement
Automatically
Automatically
Manual
Manual
Manual
Manual
Manual
In case of alert level faults 10–35:
The horn, alarm contact (additional equipment ZB) are activated and the fault is transmitted to the interface (additional ZD, ZC, ZPequipment).
Acknowledge the fault by tapping the button () or by swiping to the left (→ Fig.). The fault is no longer in the view.
Datenschutz - Data protection - Protection de données
Wir setzen Cookies ein, um Ihnen die Nutzung unserer Webseite zu erleichtern. Weitere Informationen zu Cookies finden Sie in unserer Datenschutzerklärung. We use cookies to help you use our website. More information about cookies can be found in our privacy policy. Notre site utilise des cookies afin de vous garantir un service optimal. En utilisant ce site web, vous acceptez les présentes conditions. Vous trouverez privacy policy de plus amples informations. Privacy Policy