Download page Legend Thermo-6.
Legend Thermo-6
Abbreviation | Designation | Version |
---|---|---|
Connections | ||
A | Main line | |
B | Return line | |
C | Cooling water inlet | |
D | Cooling water outlet | |
E | System water inlet | |
F | System water outlet | |
J | Compressed air inlet | ZG |
K | Compressed air outlet | ZG |
N | Mains connection cable | |
X 71 X71 | socket for external sensor | ZE |
X 72 X72 | Plug for alarm contact and external control | ZB |
X 79 X79 | Socket (HB) | |
X 91 X91 | socket (Ethernet) | |
X 114 X114 | socket (USB-Host) | |
a, b, c, ... x, y, z | Internal connections | |
Components | ||
1 | Cooling water module (KWM-Z) | |
2 | heat transfer medium module (WTM) | |
3 | integrated filter in the cooling water inlet | |
3.1 | integrated filter in the Return line | |
4 | safety valve | |
5 | pressure gauge | |
6 | cooler | |
7.1 | non return valve (Return line) | |
7.2 | non return valve for leak stopper (Return line) | ZL |
7.3 | non return valve for leak stopper | ZL |
7.4 | non return valve for leak stopper (Main line) | ZL |
7.7 | non return valve (ventilation) | |
7.13 | non return valve (mould evacuation) | |
7.17 | non return valve (filling pump pump/filling) | |
8 | air vent | |
11 | bypass with non return valve | 4T/4S |
11.1 | bypass without non return valve | 6P/6R |
12.1 | Shut-off device for cooling water and System water inlet | |
12.2 | Shut-off device for cooling water and system water outlet | |
12.5 | Shut-off device for Compressed air outlet | ZG |
25 | Mould emptying module with compressed air (ZGM) | ZG |
26 | leak stopper module (ZLM) | ZL |
27 | heater module (EHM) | |
28 | Filter mat on the bottom of bottom of unit | |
29 | lifting device | |
30 | leak stopper module (ZLM-1) | ZL |
31 | Module in Return line RLM) | |
32 | Module for mould evacuation with radial wheel pump (ZNM) | ZN |
33 | Module in Main line VLM) | |
34 | proportional module (KV 2) | HB-140/160Z61, HB-140/160/180Z62 |
A 1 A1 | Control board (USR-61) | |
A 2 A2 | Display (command) | |
A 4 A4 | unit board (GIF-61) | |
A 8.1 A8.1 | Current measurement board (ZSM-61) | |
A 14 A14 | Power supply board (PSU-61) | |
A 15 A15 | External sensor board (ZE-61) | ZE |
A 18 A18 | ground light (SPL-61) | |
BB 1 BB1 | sonic transducer 1 | |
BB 2 BB2 | sonic transducer 2 | |
BT 1 BT1 | Temperature sensor in the Main line | |
BT 2 BT2 | Temperature sensor in the return line | |
BT 6 BT6 | Temperature sensor on the cooler | HB-140/160Z61/62 |
BP 1 BP1 | Pressure sensor in the system circuit (pump return) | |
BP 2 BP2 | Pressure sensor in the Main line (pump flow) | |
BP 3 BP3 | Pressure sensor in the return line (in front of the filter in the return line) | ZF |
EH 1 EH1 | Heating 1 | |
EV 1 EV1 | Axial fan | |
FU 1 FU1 | fuse for frequency converter | |
FU 2 FU2 | fuse for frequency converter | |
FU 3 FU3 | fuse for frequency converter | |
FU 4 FU4 | transformer fuse | |
FU 5 FU5 | transformer fuse | |
FU 6 FU6 | Unit board fuse | |
HA 1 HA1 | horn | |
HL 1 HL1 | ground light (Spotlight) | |
KM 1 KM1 | main contactor | |
M 1 M1 | main pump | |
M 2 M2 | filling pump | HB-100Z61/62 with ZL, HB-140/160Z61, HB-140/160/180Z62 |
M 3 M3 | Cooling valve 1 (KV 1) | |
M 4 M4 | Cooling valve 2 (KV 2) | HB-140/160Z61, HB-140/160/180Z62 |
M 9 M9 | Valve in the Main line for mould evacuation | ZN |
QS 1 QS1 | Main switch (emergency OFF device) | |
ST 1 ST1 | Temperature limiter in the Main line (safety thermostat) | |
TC 1 TC1 | transformer | |
U 1 U1 | frequency converter | |
V 1.1 V1.1 | solid-state relay (heating 1) | |
V 1.2 V1.2 | solid-state relay (heating 1) | |
X 215 X215 | preselection of voltage | |
YV 1 YV1 | Solenoid valve (air relief) | |
YV 2 YV2 | Solenoid valve (filling) | |
YV 3 YV3 | Solenoid valve (leak stopper) | ZL |
YV 4 YV4 | solenoid valve (ventilation or compressed air) | ZG, ZL |
YV 5 YV5 | solenoid valve (pressure relief) | ZG |
YV 11 YV11 | Solenoid valve (mould evacuation) | ZG |