AbbreviationDesignationVersion
Connections

A

Main line

B

Return line

C

Cooling water inlet

D

Cooling water outlet

E

System water inlet

F

System water outlet

J

Compressed air inlet

ZG

K

Compressed air outlet

ZG

N

Mains connection cable

X 71 X71

socket for external sensor

ZE

X 72 X72

Plug for alarm contact and external control

ZB

X 79 X79

Socket (HB)


X 91 X91

socket (Ethernet)


X 114 X114

socket (USB-Host)


a, b, c, ... x, y, z

Internal connections
Components

1

Cooling water module (KWM-Z)


2

heat transfer medium module (WTM)


3

integrated filter in the cooling water inlet

3.1

integrated filter in the Return line

4

safety valve

5

pressure gauge

6

cooler

7.1

non return valve (Return line)

7.2

non return valve for leak stopper (Return line)

ZL

7.3

non return valve for leak stopper

ZL

7.4

non return valve for leak stopper (Main line)

ZL

7.7

non return valve (ventilation)

7.13

non return valve (mould evacuation)

7.17

non return valve (filling pump pump/filling)

8

air vent

11

bypass with non return valve

4T/4S

11.1

bypass without non return valve

6P/6R

12.1

Shut-off device for cooling water and System water inlet

12.2

Shut-off device for cooling water and system water outlet

12.5

Shut-off device for Compressed air outlet

ZG

25

Mould emptying module with compressed air (ZGM)

ZG

26

leak stopper module (ZLM)

ZL

27

heater module (EHM)


28

Filter mat on the bottom of bottom of unit

29

lifting device

30

leak stopper module (ZLM-1)

ZL

31

Module in Return line RLM)


32

Module for mould evacuation with radial wheel pump (ZNM)

ZN

33

Module in Main line VLM)


34

proportional module (KV 2)

HB-140/160Z61, HB-140/160/180Z62

A 1 A1

Control board (USR-61)


A 2 A2

Display (command)

A 4 A4

unit board (GIF-61)


A 8.1 A8.1

Current measurement board (ZSM-61)


A 14 A14

Power supply board (PSU-61)


A 15 A15

External sensor board (ZE-61)

ZE

A 18 A18

ground light (SPL-61)

BB 1 BB1

sonic transducer 1

BB 2 BB2

sonic transducer 2

BT 1 BT1

Temperature sensor in the Main line

BT 2 BT2

Temperature sensor in the return line

BT 6 BT6

Temperature sensor on the cooler

HB-140/160Z61/62

BP 1 BP1

Pressure sensor in the system circuit (pump return)

BP 2 BP2

Pressure sensor in the Main line (pump flow)

BP 3 BP3

Pressure sensor in the return line (in front of the filter in the return line)

ZF

EH 1 EH1

Heating 1

EV 1 EV1

Axial fan

FU 1 FU1

fuse for frequency converter
10,0 A (400/460 V) / 16,0 A (220 V)


FU 2 FU2

fuse for frequency converter
10,0 A (400/460 V) / 16,0 A (220 V)


FU 3 FU3

fuse for frequency converter
10,0 A (400/460 V) / 16,0 A (220 V)


FU 4 FU4 

transformer fuse
1,6 A (400/460 V) / 2,5 A (220 V)


FU 5 FU5

transformer fuse
1,6 A (400/460 V) / 2,5 A (220 V)


FU 6 FU6

Unit board fuse
1,6 A (220/400/460 V)


HA 1 HA1

horn

HL 1 HL1

ground light (Spotlight)


KM 1 KM1

main contactor


M 1 M1

main pump

M 2 M2

filling pump

HB-100Z61/62 with ZL, HB-140/160Z61, HB-140/160/180Z62

M 3 M3

Cooling valve 1 (KV 1)


M 4 M4

Cooling valve 2 (KV 2)

HB-140/160Z61, HB-140/160/180Z62

M 9 M9

Valve in the Main line for mould evacuation

ZN

QS 1 QS1

Main switch (emergency OFF device)

ST 1 ST1

Temperature limiter in the Main line (safety thermostat)

TC 1 TC1

transformer

U 1 U1

frequency converter

V 1.1 V1.1

solid-state relay (heating 1)

V 1.2 V1.2

solid-state relay (heating 1)

X 215 X215

preselection of voltage

YV 1 YV1

Solenoid valve (air relief)

YV 2 YV2

Solenoid valve (filling)

YV 3 YV3

Solenoid valve (leak stopper)

ZL

YV 4 YV4

solenoid valve (ventilation or compressed air)

ZG, ZL

YV 5 YV5

solenoid valve (pressure relief)

ZG

YV 11 YV11

Solenoid valve (mould evacuation)

ZG