The unit cools until all temperatures (Main line, Return line and, if available, external) are lower than the set temperature [Cooling temperature]. Pressure is then relieved and the unit switches off. Optional, a waiting time can be set, which is waited after the temperature [Cooling Temperature] has been reached before the unit switches off.

  1. Press the function button () on the basic screen. The button must be pressed for approx. ¼ s to carry out the function

Or

  1. On the home basic screen, tap the menu button
  2. Select [Functions] > [Cooling]
  3. Switch on the function with the slider

NOTE!

If, after activating the [Cooling] function, the [Mould Evacuation] function is also activated, the unit will mould evacuation before switch off.

Cooling temperature

With the [Cooling] function, the unit switches off after the set temperature [Cooling Temperature] has been reached.

  1. On the home basic screen, tap the menu button
  2. Select [Setting] > [Miscellaneous] > [Cooling Temperature]

  3. Set the parameter to the desired value

Waiting time after cooling

As soon as the temperature [Cooling Temperature] is reached, the unit waits for the set time before switching off.

  1. On the home basic screen, tap the menu button
  2. Select [Setting] > [Miscellaneous] > [Waiting Time After Cooling]

  3. Set the parameter to the desired value
  4. Switch on the function with the slider