Temperature measurement
Qualification
- Qualified personnel
Equipment needed
- Hydraulic line between Main line and Return line connection with built-in temperature sensor (minimum inner diameter 8 mm, maximum length 1 m)
- Tested temperature measuring instrument approved for reference measurement (adapted to the temperature sensor used).
- An HB-TP180 checking facility can Optional be used for temperature measurement. For further Information, see https://knowledge.hb-therm.eu
Procedure
Internal temperature sensor:
- Install the hydraulic line between Main line and Return line connection.
- Switch on the unit by tapping the I/O button .
- On the home basic screen, tap the menu button
- Select [Set Values] > [Set temperature 1]
- Set the parameter to 80°C.
- Wait until the required temperature is reached and kept constant.
- Read the main line temperature and return line temperature displayed on the unit and compare with the temperature displayed on the reference measuring instrument.
External temperature sensor:
- Close the external temperature sensor to the unit.
- Place the external temperature sensor in a reference water bath at 80°C.
- Switch on the unit by tapping the I/O button .
- Read the temperature of the external sensor shown on the unit and compare it with the temperature of the reference water bath.
Calibrate temperature sensor
- If the deviation is <3 °C, the temperature measurement is within the tolerance range.
- If the deviation is >3 °C, the unit's temperature sensor must be checked. For larger linear errors, the individual temperature sensor can be calibrated → [Service] > [Calibrating] > [Temperature] > [.. ]
If you have any questions, please contact your HB-Therm country representative (www.hb-therm.com).