Download page Set a separate connection for system water.
Set a separate connection for system water
The water requirements in the cooling circuit may differfrom those in the system circuit. One solution is to fill the system circuit not with cooling water, but with treated water via a separate connection for the system water. If necessary, the common connection for cooling water and system water can be converted into separate connections. In this way, the respective requirements for both water circuits can be met.
Equipment needed:
Torx screwdriver
Slotted screwdriver
Cooling and system water inlet
Remove the screws (1) with a Torx screwdriver and remove the mounting brackets.
Insert a flathead screwdriver into the groove of the connector pin (2) and push it out as a whole.
Remove the turning pin (3) by hand and insert it upside down.
Reinstall the connector pin (2).
Install the mounting brackets and re-tighten the screws (1) with a Torx screwdriver.
Cooling and system water outlet
Remove the screws (4) with a Torx screwdriver and remove the mounting brackets.
Insert a flathead screwdriver into the groove of the connector pin (5) and push it out as a whole.
Remove the turning pin (6) and insert it upside down.
Reinstall the connector pin (5).
Install the mounting brackets and re-tighten the screws (4) with a Torx screwdriver.
Datenschutz - Data protection - Protection de données
Wir setzen Cookies ein, um Ihnen die Nutzung unserer Webseite zu erleichtern. Weitere Informationen zu Cookies finden Sie in unserer Datenschutzerklärung. We use cookies to help you use our website. More information about cookies can be found in our privacy policy. Notre site utilise des cookies afin de vous garantir un service optimal. En utilisant ce site web, vous acceptez les présentes conditions. Vous trouverez privacy policy de plus amples informations. Privacy Policy