Download page Detect the cause of the fault, Beer-6.
Detect the cause of the fault, Beer-6
Help with problems
Problem
Remedying
Beer is too warm
Beer-6 switched on just a short time ago? → To maintain a good cooling capacity, the Beer-6 must be switched on at least 10 min before serving.
There is no beer coming
Are all hose lines connected correctly? → Perhaps beer flexible tube has been interchanged with CO2 hose line?
CO2 valve open?
CO2 bottle empty?
Is the gas pressure correctly adjusted on the pressure reducer pressure adjustment screw? → An optimal tap pressure is between 1.5 and 3.0 bar.
Shut-off valves open?
Beer keg empty?
Beer foams too much
CO2 pressure too high?
Stored beer too warm?
Beer stored too long and enriched with CO2?
Beer contains too little carbonic acid
CO2 bottle empty?
CO2 pressure too low?
Shut-off valves open?
Compressor is not running
Power supply available (Beer-6 switched on)?
Contact your HB-Therm country representative
Datenschutz - Data protection - Protection de données
Wir setzen Cookies ein, um Ihnen die Nutzung unserer Webseite zu erleichtern. Weitere Informationen zu Cookies finden Sie in unserer Datenschutzerklärung. We use cookies to help you use our website. More information about cookies can be found in our privacy policy. Notre site utilise des cookies afin de vous garantir un service optimal. En utilisant ce site web, vous acceptez les présentes conditions. Vous trouverez privacy policy de plus amples informations. Privacy Policy