Basic data
Type

HB-100Z62

HB-140Z62

HB-160Z62

HB-180Z62

Temperature max.

100 °C

140 °C

160 °C

180 °C

Circulating volume in unit (approx.)

4T/4S: 2,0 L

6P/6R: 3,0 L

Dimensions

Height/ width/ depth

650 mm / 300 mm / 991 mm

Weight max.

4T: 73 kg

6P: 86 kg

4S: 78 kg

6R: 90 kg

Environment
Temperature range

5–40 °C

Relative humidity

35–85 % RH(non-condensing)

Continuous sound pressure level

<70 dB(A)

Surface temperature (back of the device )

>55 °C

Cleanroom capability

«At Rest» <ISO Classe 6 (Cl. 1000)

«In Operation» ISO Classe 7 (Cl. 10 000)

Temperature measurement
Resolution

0,1 °C

Control accuracy

±0,1 °C

Tolerance

±0,8 °C

Flow rate measurement
Measuring range

4T/4S: 0,4–60 L/min

6P/6R: 1–150 L/min

Resolution

0,1 L/min

Tolerance

4T/4S:± (5% of measured value + 0,1 L/min)

6P/6R:± (5% of of measured value + 0.25 l/min)

Pump pressure indicator
Tolerance

± 10% of of rated value


Hydraulic data
Connection

HB-100Z62

HB-140Z62

HB-160Z62

HB-180Z62

Main line, Return line

Pump thread

4T/4S: G¾

6P/6R: G1¼

Resistance (including external heat transfer circuit)

20 bar, 120 °C

20 bar, 160 °C

20 bar, 180 °C

25 bar, 200 °C

cooling water
Pressure

2–5 bar **

Thread when cooling

A2 (40 kW @ 60 K): G⅜

B2 (65 kW @ 60 K): G⅜

E2 (120 kW @ 60 K): G¾

Resistance

10 bar, 100 °C

Separate cooling water
Pressure

2–5 bar **

Thread when cooling

A2 (40 kW @ 60 K): G¼

B2 (65 kW @ 60 K): G¼

E2 (120 kW @ 60 K): G½

Resistance

10 bar, 100 °C

Compressed air (additional equipment ZG)
Pressure

2–8 bar *

Pump thread

4T/4S: G¼ (AIR IN, AIR OUT)

6P/6R: G⅜ (AIR IN), G½ (AIR OUT)

Resistance

10 bar, 100 °C

Drain (only with 6P/6R radial wheel pump, without additional equipment ZG/ZN)

Thread

* Mould emptying is more efficient with higher compressed air.

** We recommend a pressure differential of at least 2 bar between cooling water inlet and outlet. A smaller difference reduces the cooling capacity and extends the venting process.


Electrical data
Residual current circuit-breakerWe recommend using a type B residual current circuit breaker (RCD), as the temperature control units are equipped with a frequency converter. Type A RCD are not suitable. The leakage current is max. 5 mA per unit.
Mains cable to unit

3LPE, 4 m (Standard)

H07RN-F (Standard) / H07BQ-F (CE)

SO/SOW/SOOW (UL/CSA)

Cross-section

400/460 V

8 kW:   4x2,5 mm2 (CE) / 4xAWG 12 (UL/CSA)

16 kW: 4x6,0 mm2 (CE) / 4xAWG 10 (UL/CSA)

32 kW: 4x16,0 mm2 (CE) / 4xAWG 4 (UL/CSA)

220 V

8 kW:   4x6,0 mm2 (CE) / 4xAWG 10 (UL/CSA)

16 kW: 4x16,0 mm2 (CE) / 4xAWG 4 (UL/CSA)

32 kW: 4x50,0 mm2 (CE) / 4xAWG 2 (UL/CSA)

Network system

TN-System

A network system with a grounded protective conductor is common in Europe. The unit can be connected to this network system and operated without additional measures.

High-Leg-Delta-System

A grid system in which a midpoint is grounded between two phases is common in Asia and North America. Starting with software-version SW61-1_2401, The unit can be connected and operated to this network system without additional measures.

Corner-Grounded-Delta-System

A grid system in which one phase is grounded is common in Asia and North America. Starting with software-version SW61-1_2401, The unit can be connected and operated to this network system without additional measures.

IT-System

In a network system without a galvanic connection between active conductors and grounded parts, additional measures are required:

  • When connection to this network system, remove the IT screw at the inlet of the frequency inverter (Fig.). Otherwise, the leakage currents of the frequency converter may trigger the residual current circuit breaker.

operation without an IT screw poses no safety risk, but EMC interference emissions can increase. Compliance with EMC limits is the responsibility of the operator.

Heating capacityThe heating capacity is valid at Mains voltage (220 V, 400 V, 460 V) with internal heating capacity limitation and varies by max. ± 10% within the specified voltage range.
Mains voltagesee nameplate on the unit
Maximum fusingsee nameplate on the unit
Rated short circuit current

6 kA   (Imax ≤ 63 A)

10 kA (Imax = 125 A)

Overvoltage category

II

Degree of contamination

2

Protection class

IP 44