Faults are signaled on the basic screen in the status field and by the LED status luminaire (spotlight) on the bottom of the unit. In addition, an acoustic alarm (horn) informs the operator in the event of a fault. By tapping on the status field (info symbol ), the information system opens. The information system displays general device information as well as information about faults and warnings that occur.
Alert levels
A distinction is made between the following alarm levels, which trigger corresponding reactions. For an overview of the faults, click here...
Alert level
03
05
10
13
20
30
33
35
Status field/Spotlight
yellow
yellow
yellow
yellow
red
red
red
red
heating
-
Off
-
-
Off
Off ¹
Off
Off
Pump
-
-
-
-
-
Off
Off
Off
cooling
-
-
-
-
-
Off
Off
Off
horn
-
-
active
active
active
active
active
active
alarm contact
-
-
active
active
active
active
active
active
Alarm on interface
-
-
active
active
active
active
active
active
Alarm acknowledgement
manual
automatically
automatically
manual
manual
manual
manual
manual
Alarm output delay
Yes
No
Yes
No
Yes
Yes
No
Yes
¹ Once the alarm is detected, the heating is switched off immediately. The edition of the alarm and further reactions are delayed.
In case of alarm level faults 03–35:
Horn, alarm contact (additional equipment ZB) are activated and the fault is transmitted to the interface (additional ZD, ZC, ZPequipment).
Acknowledge the fault by tapping on the button or by swiping to the left (Fig.). The fault is no longer present in the view.
Datenschutz - Data protection - Protection de données
Wir setzen Cookies ein, um Ihnen die Nutzung unserer Webseite zu erleichtern. Weitere Informationen zu Cookies finden Sie in unserer Datenschutzerklärung. We use cookies to help you use our website. More information about cookies can be found in our privacy policy. Notre site utilise des cookies afin de vous garantir un service optimal. En utilisant ce site web, vous acceptez les présentes conditions. Vous trouverez privacy policy de plus amples informations. Privacy Policy