HB-GATE61 data
power supply | |
with power supply | power supply 85–265 VAC / 24 VDC, 36 W (T28949) To supply power to the Gate-6 interface server, we recommend either a direct connection to the machine control (24 VDC) or the use of the power supply. NOTE! The product must be powered by an SELV/LPS power supply (max. Output of 6.25 A @24 VDC) with reinforced or double insulation. The power supply must be protected against short circuits and overloads. |
with Thermo-6 | cable HB/Gate-6 (Sub-D 15-p./Plug 3-p.), 5 m (T29390-502) If no Flow Meter Flow-5 act connected to the Thermo-6 temperature control unit, the power can alternatively be supplied via the 'HB' interface of the temperature control unit with the cable. NOTE! Note that the simultaneous power supply of Gate-6 and Flow-5 is not possible for performance reasons. |
environment | |
Temperature | 5–40 °C |
Relative humidity | 35–85 % RH(non-condensing) |
Dimensions (Dimensions ) | |
Height | 275 mm |
Width | 190 mm |
Depth | 67 mm |
Weight max. | 1,8 kg |
Maximum Bluetooth range | 10 mwith a clear view |
frequency band | |
WLAN | 2,4 GHz / 5,0 GHz |
Bluetooth | 2,4 GHz |
Overvoltage category | I |
Degree of contamination | 2 |
Protection class | IP 44 |
Cleanroom capability | ISO Classe 6 (Cl. 1000) |