We recommend using a type B residual current circuit breaker (RCD), as the temperature control units are equipped with a frequency converter. Type A RCD are not suitable. The leakage current is max. 5 mA per unit.
Mains cable to unit
3LPE, 4m (as standard)
H07RN-F (Standard)/H07BQ-F (CE)
SO/SOW/SOOW (UL/CSA)
cross-section
400/460V, 8kW: 4x2.5mm2 (CE)/4xAWG 12 (UL/CSA)
400/460V, 16kW: 4x6.0 mm2 (CE)/4xAWG10 (UL/CSA)
220V, 8kW: 4x6.0 mm2 (CE)/4xAWG10 (UL/CSA)
220V, 16kW: 4x16.0 mm2 (CE)/4xAWG 4 (UL/CSA)
Network system
TN (network with protective conductor)
Mains voltage
see nameplate on the unit
maximum fusing
Rated short circuit current
6 kA
Overvoltage category
II
Degree of contamination
2
Protection class
IP44
Datenschutz - Data protection - Protection de données
Wir setzen Cookies ein, um Ihnen die Nutzung unserer Webseite zu erleichtern. Weitere Informationen zu Cookies finden Sie in unserer Datenschutzerklärung. We use cookies to help you use our website. More information about cookies can be found in our privacy policy. Notre site utilise des cookies afin de vous garantir un service optimal. En utilisant ce site web, vous acceptez les présentes conditions. Vous trouverez privacy policy de plus amples informations. Privacy Policy